ABB Current Monitoring Relay, 1 Phase, SPDT, DIN Rail
- RS庫存編號:
- 775-7977
- 製造零件編號:
- 1SVR730840R0200 CM-SRS.11S
- 製造商:
- ABB
此圖片僅供參考,請參閲產品詳細資訊及規格
小計(1 件)*
HK$1,879.30
訂單超過 HK$250.00 免費送貨
有庫存
- 5 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$1,879.30 |
* 參考價格
- RS庫存編號:
- 775-7977
- 製造零件編號:
- 1SVR730840R0200 CM-SRS.11S
- 製造商:
- ABB
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | ABB | |
| Monitoring Application | Current | |
| Electrical Phase | 1 | |
| Contact Configuration | SPDT | |
| Mounting Type | DIN Rail | |
| Minimum Current Sensed | 0.1 A, 3 mA, 10mA | |
| Maximum Current Sensed | 1 A, 30 mA, 100mA | |
| Current Sensitivity | Overcurrent, Undercurrent | |
| Series | CM-SRS | |
| Height | 85.6mm | |
| Length | 103.7mm | |
| Minimum Operating Temperature | -20°C | |
| Dimensions | 103.7 x 22.5 x 85.6mm | |
| Maximum Operating Temperature | +60°C | |
| Width | 22.5mm | |
| Terminal Type | Screw | |
| Operating Temperature Range | +60°C | |
| Current Range | 0.1 → 1 A, 10 → 100 mA, 3 → 30mA | |
| 選取全部 | ||
|---|---|---|
品牌 ABB | ||
Monitoring Application Current | ||
Electrical Phase 1 | ||
Contact Configuration SPDT | ||
Mounting Type DIN Rail | ||
Minimum Current Sensed 0.1 A, 3 mA, 10mA | ||
Maximum Current Sensed 1 A, 30 mA, 100mA | ||
Current Sensitivity Overcurrent, Undercurrent | ||
Series CM-SRS | ||
Height 85.6mm | ||
Length 103.7mm | ||
Minimum Operating Temperature -20°C | ||
Dimensions 103.7 x 22.5 x 85.6mm | ||
Maximum Operating Temperature +60°C | ||
Width 22.5mm | ||
Terminal Type Screw | ||
Operating Temperature Range +60°C | ||
Current Range 0.1 → 1 A, 10 → 100 mA, 3 → 30mA | ||
- COO (Country of Origin):
- DE
CM-SRS Current Monitoring, Single Phase AC/DC
Depending on the configuration, the current monitoring relays CM-SRS.1 and CM-SRS.2 can be used for over- or undercurrent monitoring in single-phase AC and/or DC systems. The current to be monitored (measured value) is applied to terminals B1/B2/B3-C. The devices work according the open-circuit principle.
If the measured value exceeds resp. drops below the adjusted threshold value, the output relay(s) energize(s): on the CM-SRS.1 immediately, on the CM-SRS.2 after the set tripping delay TV.
Monitoring of DC- and AC-currents: CM-SRS.x1: 3mA - 1A and CM-SRS.x2: 0.3-15A
RMS measuring principle
One device includes 3 measuring ranges
Over- or undercurrent monitoring configurable
Hysteresis adjustable from 3-30%
Tripping delay TV adjustable 0.1-30s
CM-SRS.1: 1 c/o contact
CM-SRS.2: 2 c/o contacts
22.5mm width
3 LED's for status indication
RMS measuring principle
One device includes 3 measuring ranges
Over- or undercurrent monitoring configurable
Hysteresis adjustable from 3-30%
Tripping delay TV adjustable 0.1-30s
CM-SRS.1: 1 c/o contact
CM-SRS.2: 2 c/o contacts
22.5mm width
3 LED's for status indication
相关链接
- ABB Current Monitoring Relay SPDT
- ABB Current Monitoring Relay SPDT, DIN Rail
- ABB Temperature Monitoring Relay DIN Rail
- ABB Current Monitoring Relay DPDT, DIN Rail
- ABB Temperature Monitoring Relay SPDT, DIN Rail
- ABB Temperature Monitoring Relay SPDT, DIN Rail
- ABB Phase 3 Phase 90 → 170V ac, DIN Rail
- ABB Frequency 1 SPDT, DIN Rail