Gossen Metrawatt PROFiTEST PRIME Multifunction Tester 50V With USB
- RS庫存編號:
- 260-8278
- 製造零件編號:
- M516G
- 製造商:
- Gossen Metrawatt
小計(1 件)*
HK$73,558.40
訂單超過 HK$250.00 免費送貨
有庫存
- 加上 1 件從 2026年11月09日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$73,558.40 |
* 參考價格
- RS庫存編號:
- 260-8278
- 製造零件編號:
- M516G
- 製造商:
- Gossen Metrawatt
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Gossen Metrawatt | |
| Product Type | Multifunction Tester | |
| Loop Impedance Test Type | 2 Wire, 3 Wire | |
| Automatic RCD Test | Yes | |
| Model Number | PROFiTEST PRIME | |
| RCD Ramp Test | Yes | |
| Non-Tripping | Yes | |
| Insulation Test Voltage | 50V | |
| Maximum Voltage Measurement | 230V | |
| Earth Resistance Measurement | No | |
| Downloadable Data | No | |
| Interface Type | USB | |
| Continuity Test Current | 1.6mA | |
| RCD Test Type | Type A | |
| Standards/Approvals | EN 501101, IEC 603646, RoHS | |
| Remote Switch Mode | Yes | |
| Weight | 10.15kg | |
| Test Standards | DIN VDE 0100-600, EN 61010 | |
| IP Rating | IP40 | |
| Power Source | Battery | |
| Safety Category Level | CAT IV, CAT III | |
| Safety Category Voltage | 300V | |
| Battery Type | Rechargeable | |
| Maximum Operating Temperature | +50°C | |
| Minimum Operating Temperature | +5°C | |
| 選取全部 | ||
|---|---|---|
品牌 Gossen Metrawatt | ||
Product Type Multifunction Tester | ||
Loop Impedance Test Type 2 Wire, 3 Wire | ||
Automatic RCD Test Yes | ||
Model Number PROFiTEST PRIME | ||
RCD Ramp Test Yes | ||
Non-Tripping Yes | ||
Insulation Test Voltage 50V | ||
Maximum Voltage Measurement 230V | ||
Earth Resistance Measurement No | ||
Downloadable Data No | ||
Interface Type USB | ||
Continuity Test Current 1.6mA | ||
RCD Test Type Type A | ||
Standards/Approvals EN 501101, IEC 603646, RoHS | ||
Remote Switch Mode Yes | ||
Weight 10.15kg | ||
Test Standards DIN VDE 0100-600, EN 61010 | ||
IP Rating IP40 | ||
Power Source Battery | ||
Safety Category Level CAT IV, CAT III | ||
Safety Category Voltage 300V | ||
Battery Type Rechargeable | ||
Maximum Operating Temperature +50°C | ||
Minimum Operating Temperature +5°C | ||
- COO (Country of Origin):
- DE
Gossen-Metrawatt Multifunction Tester, 230V Maximum Voltage Measurement, 50V Insulation Test Voltage - M516G
This multifunction tester is a portable, battery-operated instrument designed for comprehensive electrical installation verification and protection device assessment. It combines loop impedance, RCD testing and insulation/continuity checks for field technicians. The unit operates within a wide ambient range and connects to external tools via a USB interface.
Features and Benefits:
• *Made in Germany
• CAT IV/CAT III electrical tester for high-safety site testing
• Loop impedance 2-wire/3-wire tester enabling versatile circuit checks
• RCD Type A ramp test multifunction tester for sensitive device evaluation
• Non-tripping continuity tester 1.6 mA reduces nuisance tripping during faults
• Rechargeable insulation/continuity tester 50 V allowing repeated field use
• CAT IV/CAT III electrical tester for high-safety site testing
• Loop impedance 2-wire/3-wire tester enabling versatile circuit checks
• RCD Type A ramp test multifunction tester for sensitive device evaluation
• Non-tripping continuity tester 1.6 mA reduces nuisance tripping during faults
• Rechargeable insulation/continuity tester 50 V allowing repeated field use
Applications
• Suitable for on-site periodic electrical installation verification
• Used for commissioning protective devices in distribution boards
• Ideal for testing RCDs requiring ramp and automatic sequences
• Can be used for continuity checks without causing circuit trips
• Used with portable setups where USB data transfer is required
• Used for commissioning protective devices in distribution boards
• Ideal for testing RCDs requiring ramp and automatic sequences
• Can be used for continuity checks without causing circuit trips
• Used with portable setups where USB data transfer is required
What safety category and voltage rating does it support?
It is rated for CAT IV and CAT III use and supports measurements up to 300 V safety-category voltage.
How does the unit perform RCD testing automatically?
It executes automatic RCD tests including ramp profiles for Type A devices and supports remote switch control during test sequences.
What environmental conditions allow reliable operation?
The instrument is specified to operate between +5 °C and +50 °C and has an ingress protection rating of IP40.
How is data transferred from the device?
Data can be extracted using the built-in USB Interface for connection to compatible systems.
What are the power and portability characteristics?
It runs from a rechargeable battery, is battery-powered for field use and weighs 10.15 kg.
相关链接
- Gossen Metrawatt PROFITEST PRIME Starter Package Multifunction Tester 1kV With USB
- Gossen Metrawatt PROFITEST EMOBILITY Multifunction Tester 50V With Bluetooth
- Gossen Metrawatt PROFITEST REMOTE Multifunction Tester 300V With RS232
- Gossen Metrawatt Z506Z HV-P Profitest Prime
- Gossen Metrawatt PROFiTEST MF TECH Multifunction Tester 600V Earth Resistance Measurement With USB
- Gossen Metrawatt PROFiTEST MF XTRA Multifunction Tester 600V Earth Resistance Measurement With USB
- Gossen Metrawatt PROFITEST PVSUN Multifunction Tester 1kV Earth Resistance Measurement With USB 2.0
- Gossen Metrawatt PROFiTEST MF XTRA - LEMONGREEN Multifunction Tester 600V Earth Resistance Measurement With USB