Fluke 1587 Advanced Motor and Drive Troubleshooting Multimeter Kit

小計(1 件)*

HK$16,105.80

Add to Basket
選擇或輸入數量
有限的庫存
  • 2 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$16,105.80

* 參考價格

RS庫存編號:
905-5923
Distrelec 貨號:
300-47-588
製造零件編號:
FLUKE-1587/MDT FC
製造商:
Fluke
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Fluke

Model Number

1587

Product Type

Multimeter Kit

Application

Electrical

Kit Contents

AC Current Clamp, Phase Rotation Indicator, Multimeter

Kit Type

Advanced Motor and Drive Troubleshooting

Standards/Approvals

TUV, UL, CE, CSA

豁免

COO (Country of Origin):
CN

Fluke Multimeter Kit, Advanced Motor and Drive Troubleshooting Kit Type, Electrical Application - FLUKE-1587/MDT FC


This multimeter kit combines a true-rms digital multimeter with insulation test capability and targeted accessories for Advanced motor and drive troubleshooting in industrial settings. It is built for field service and preventative maintenance, providing insulation resistance measurements across multiple test voltages alongside standard multimeter functions and connectivity for data capture and analysis.

Features & Benefits


• Insulation range 0.01MΩ–2GΩ enabling high-resistance diagnosis
• Test voltages 50V–1000V for diverse insulation tasks
• Live-circuit detection inhibits tests above 30V for safety
• VFD low-pass filter improves motor drive voltage readings
• AC/DC current and voltage measurements with true-rms response
• Wireless data transfer for timed PI/DAR trend analysis

**Applications**


• Suitable for commissioning and fault-finding on VFD systems
• Ideal for preventative insulation surveys on motors and cables
• Used for on-site motor drive diagnostics with AC current clamp
• Can be used for electrical maintenance in automation plants
• Used with phase rotation indicator for rotating machinery checks

What battery type and expected operational endurance does it use


It runs on four AA batteries and supports about 1000 hours of meter use with standard alkaline cells.

How does the tool manage capacitive discharge after testing


The instrument auto-discharges capacitive voltage in under 0.5 s for C ≤ 1 μF to remove stored charge before handling.

Which environmental conditions affect operation limits


It operates between -20°C and 55°C and tolerates up to 95% non‑condensing humidity at 10°C–30°C with reduced limits at higher temperatures.

What protection is provided for current input overloads


The mA input is fuse-protected with a 0.44 A, 1000V fuse and allows 600 mA overload for short periods.

How are frequency and capacitance measured for diagnostics


Frequency measurement extends to 99.99 kHz with high resolution and capacitance ranges up to 9999 μF for motor and component testing.