暫時無法供應
抱歉,我們不知道何時會到貨。
- RS庫存編號:
- 794-3092
- 製造零件編號:
- AM-520-EUR
- 製造商:
- Amprobe
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Amprobe | |
| Product Type | Multimeter | |
| Multimeter Type | Digital | |
| Display Type | Digital | |
| Functions Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance, Temperature | |
| True RMS | No | |
| DC Voltage Accuracy | ±0.8 % rdg + 1 Digits | |
| AC Voltage Accuracy | ±1 % rdg + 3 Digits | |
| DC Current Accuracy | ±1 % rdg + 2 Digits | |
| AC Current Accuracy | ± 1.2 % rdg + 3 Digits | |
| Maximum Frequency | 400Hz | |
| Resistance Measurement Accuracy | ±1.2 % rdg + 2 Digits | |
| Height | 45mm | |
| Length | 182mm | |
| Width | 90mm | |
| Standards/Approvals | No | |
| Weight | 354g | |
| Safety Category Level | CAT II, CAT III | |
| Safety Category Voltage | 1000V | |
| 選取全部 | ||
|---|---|---|
品牌 Amprobe | ||
Product Type Multimeter | ||
Multimeter Type Digital | ||
Display Type Digital | ||
Functions Measured AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance, Temperature | ||
True RMS No | ||
DC Voltage Accuracy ±0.8 % rdg + 1 Digits | ||
AC Voltage Accuracy ±1 % rdg + 3 Digits | ||
DC Current Accuracy ±1 % rdg + 2 Digits | ||
AC Current Accuracy ± 1.2 % rdg + 3 Digits | ||
Maximum Frequency 400Hz | ||
Resistance Measurement Accuracy ±1.2 % rdg + 2 Digits | ||
Height 45mm | ||
Length 182mm | ||
Width 90mm | ||
Standards/Approvals No | ||
Weight 354g | ||
Safety Category Level CAT II, CAT III | ||
Safety Category Voltage 1000V | ||
豁免
- COO (Country of Origin):
- CN
Fluke Multimeter, 400Hz Maximum Frequency, 354g Weight - AM-520-EUR
This multimeter is a handheld instrument designed for HVAC and electrical professionals to measure a wide range of electrical and temperature parameters in field environments. It provides voltage, current, resistance, capacitance and temperature measurement capability together with non-contact voltage detection and practical on-tool conveniences for troubleshooting and maintenance tasks.
Features & Benefits
• AC current accuracy ±1.2% rdg+3 digits supports precise HVAC current checks
• DC voltage ±0.8% rdg+1 digit for accurate DC system diagnostics
• Frequency measurement to 10MHz aids motor and signal verification
• Capacitance and temperature ranges verify motor start capacitors
• VolTect™ non-contact voltage detection improves safety during inspection
• Built-in torch and probe holder enable hands-free, low-light work
• DC voltage ±0.8% rdg+1 digit for accurate DC system diagnostics
• Frequency measurement to 10MHz aids motor and signal verification
• Capacitance and temperature ranges verify motor start capacitors
• VolTect™ non-contact voltage detection improves safety during inspection
• Built-in torch and probe holder enable hands-free, low-light work
**Applications**
• Suitable for flame-sensor micro-amp measurements during burner servicing
• Ideal for checking motor start-up capacitors and run components
• Used for verifying AC and DC supplies on automation panels
• Can be used for temperature checks on vents, transformers and fuses
• Used with field wiring to confirm continuity and diode behaviour
• Ideal for checking motor start-up capacitors and run components
• Used for verifying AC and DC supplies on automation panels
• Can be used for temperature checks on vents, transformers and fuses
• Used with field wiring to confirm continuity and diode behaviour
What measurement ranges are available for current and voltage?
It measures up to 10A for AC/DC current and up to 600V for both AC and DC ranges with autoranging and manual-ranging options.
How does the instrument display changing signals?
The backlit LCD includes an analogue bar graph to help monitor fast-changing values alongside numeric readings.
Which temperature probe type is supplied and what is the temperature span?
A K-type thermocouple probe is provided and the input covers −40°C to 1000°C.
What capacitance and frequency capabilities support motor diagnostics?
Capacitance ranges span from tens of nF to thousands of μF and frequency measurement extends from 10Hz to 10MHz for comprehensive component checks.
How is continuity and diode testing indicated?
Audible continuity is included and a diode-test function provides forward-voltage verification for rectifiers and semiconductor checks.
Standards
CAT III 600V, CAT II 1000V
Supplied with
• 1 x 9V(6F22) battery installed
• Test leads
• 1 x Type-K probe
• Velcro strap
• Carrying case and users manual
• Test leads
• 1 x Type-K probe
• Velcro strap
• Carrying case and users manual
相关链接
- Amprobe 33XRA Handheld Digital Multimeter
- Amprobe DM73C Handheld Digital Multimeter
- Amprobe 30XR-A Handheld Digital Multimeter
- Amprobe 35XPA Handheld Digital Multimeter
- Amprobe 37XRA Handheld Digital Multimeter True RMS
- Amprobe 34XRA Handheld Digital Multimeter True RMS
- Amprobe 38XRA Handheld Digital Multimeter True RMS
- Amprobe PM55A Handheld Digital Multimeter 2 mA dc