Omron H3DT Series DIN Rail Timer, 2-Contact, 240 V dc 100V ac, 120 V ac, 1 to 120 s, 1-Function, SPDT Switch
- RS庫存編號:
- 106-6246
- 製造零件編號:
- H3DT-HCL 100-120VAC
- 製造商:
- Omron
小計(1 件)*
HK$982.10
訂單超過 HK$250.00 免費送貨
暫時缺貨
- 2 件從 2026年10月20日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$982.10 |
* 參考價格
- RS庫存編號:
- 106-6246
- 製造零件編號:
- H3DT-HCL 100-120VAC
- 製造商:
- Omron
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Omron | |
| Product Type | Timer | |
| Mount Type | DIN Rail | |
| Function | Offset Double Ring End | |
| Time Range | 1 to 120 s | |
| Number of Contacts | 2 | |
| Switching Voltage | 250V ac | |
| Number of Timer Functions | 1 | |
| Contact Configuration | SPDT | |
| IP Rating | IP30, IP20 | |
| Supply AC Voltage | 100V ac, 120V ac | |
| Minimum Operating Temperature | -20°C | |
| Contact Current | 5A | |
| Supply DC Voltage | 240 V dc | |
| Timing Adjustment | Dial | |
| Mode | Power-Off Delay | |
| Maximum Operating Temperature | 60°C | |
| Terminal Type | Push-in | |
| Width | 90mm | |
| Standards/Approvals | cULus:UL 508/CSA C22.2 No. 14EN 61812-1CCCLRDNV GLIEC 60664-1 4 kV/2RoHS | |
| Length | 17.5mm | |
| Height | 100mm | |
| Series | H3DT | |
| 選取全部 | ||
|---|---|---|
品牌 Omron | ||
Product Type Timer | ||
Mount Type DIN Rail | ||
Function Offset Double Ring End | ||
Time Range 1 to 120 s | ||
Number of Contacts 2 | ||
Switching Voltage 250V ac | ||
Number of Timer Functions 1 | ||
Contact Configuration SPDT | ||
IP Rating IP30, IP20 | ||
Supply AC Voltage 100V ac, 120V ac | ||
Minimum Operating Temperature -20°C | ||
Contact Current 5A | ||
Supply DC Voltage 240 V dc | ||
Timing Adjustment Dial | ||
Mode Power-Off Delay | ||
Maximum Operating Temperature 60°C | ||
Terminal Type Push-in | ||
Width 90mm | ||
Standards/Approvals cULus:UL 508/CSA C22.2 No. 14EN 61812-1CCCLRDNV GLIEC 60664-1 4 kV/2RoHS | ||
Length 17.5mm | ||
Height 100mm | ||
Series H3DT | ||
Omron H3DT Series Timer, 1 to 120s Time Range, 100V AC Supply Voltage - H3DT-HCL 100-120VAC
This timer is a DIN-rail mounted time relay designed for industrial control and automation panels, providing selectable delay timing for switching tasks in electrical systems. It accepts AC or DC supplies and offers an adjustable timing window suitable for sequential control, interlocking and delay-based operations in factory and building installations.
Features and Benefits:
• 1-120s timing range enables fine control of delay intervals
• SPDT contact arrangement allows changeover switching between circuits
• Push-in terminals speed installation and reduce wiring time
• 5A contact rating supports moderate load switching tasks
• 100VAC-120VAC and 240VDC supply options suit varied power architectures
• IP30 protection rating offers Basic panel dust defence
• SPDT contact arrangement allows changeover switching between circuits
• Push-in terminals speed installation and reduce wiring time
• 5A contact rating supports moderate load switching tasks
• 100VAC-120VAC and 240VDC supply options suit varied power architectures
• IP30 protection rating offers Basic panel dust defence
Applications
• Suitable for sequence control in conveyor and material-handling systems
• Used for interlock timing on motor starter circuits
• Ideal for delay functions in HVAC control panels
• Can be used for timed lighting control in industrial facilities
• Used with relay logic for safety timing and reset sequences
• Used for interlock timing on motor starter circuits
• Ideal for delay functions in HVAC control panels
• Can be used for timed lighting control in industrial facilities
• Used with relay logic for safety timing and reset sequences
What Terminal style does it use for connection and what is the benefit?
It uses push-in terminals which permit tool-free conductor insertion, reducing assembly time and improving consistency during wiring.
How does the contact configuration affect wiring options?
The SPDT configuration provides a common output that can switch between normally open and normally closed circuits, enabling alternative routing without extra relays.
What environmental temperatures can it operate within?
The device is rated for operation from -20°C up to 60°C, allowing use across typical indoor industrial temperature ranges.
Which standards and approvals are relevant for integration into control panels?
It carries multiple approvals including UL 508 and EN 61812-1, facilitating incorporation into systems that require recognised safety and performance assessments.
What switching voltage and current constraints should installers observe?
The maximum switching voltage is 250VAC and contact current is 5A, so loads should be selected or interfacing devices used accordingly.
相关链接
- Omron H3DT Series DIN Rail Timer Relay 240 V 100V ac 1 to 120 s SPDT Switch
- Omron H3YN Series Timer Relay 100 to 120 V ac 100V ac 0.1 to 600 min
- Omron H3DK Series DIN Rail Timer Relay 24 to 240 V dc 100V ac 1 to 120 s
- Omron H3YN Series Timer Relay 100 to 120 V ac 100V ac 0.1 to 600 s DPDT
- Omron H3YN Series Timer Relay 100 to 120 V ac 100V ac 0.1 to 600 s 4PDT
- Omron H3DT Series DIN Rail Timer 240 V dc 200V ac 1 to 120 s SPDT Switch
- Omron H3DT Series DIN Rail Timer Relay 24 to 240 V 24V ac 1 to 120 s SPDT Switch
- Omron H3YN Series Panel Timer Relay 125 V 100V ac 0.1 min to 10 h DPDT