Omron H3YN Series DIN Rail, Panel Mount Timer Relay, 24V ac, 4-Contact, 0.1 s → 10min
- RS庫存編號:
- 236-1391
- 製造零件編號:
- H3YN-4 AC24
- 製造商:
- Omron
小計(1 件)*
HK$830.50
訂單超過 HK$250.00 免費送貨
有庫存
- 加上 8 件從 2025年12月22日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$830.50 |
* 參考價格
- RS庫存編號:
- 236-1391
- 製造零件編號:
- H3YN-4 AC24
- 製造商:
- Omron
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Omron | |
| Supply Voltage | 24V ac | |
| Mounting Type | DIN Rail, Panel Mount | |
| Mode of Operation | Flicker OFF Start, Flicker ON Start, Interval, ON Delay | |
| Time Range | 0.1 s → 10min | |
| Number of Contacts | 4 | |
| Number of Timer Functions | Multi Function | |
| Time Increment | Minutes, Seconds | |
| Maximum Current | 3A | |
| Maximum Voltage | 250V ac | |
| Switch Configuration | 4PDT | |
| Terminal Type | Socket | |
| Power Supply | External | |
| Width | 21.5mm | |
| Maximum Operating Temperature | +50°C | |
| Depth | 63mm | |
| Series | H3YN | |
| Length | 28mm | |
| Time Delay | 0.1s | |
| Minimum Operating Temperature | -10°C | |
| 選取全部 | ||
|---|---|---|
品牌 Omron | ||
Supply Voltage 24V ac | ||
Mounting Type DIN Rail, Panel Mount | ||
Mode of Operation Flicker OFF Start, Flicker ON Start, Interval, ON Delay | ||
Time Range 0.1 s → 10min | ||
Number of Contacts 4 | ||
Number of Timer Functions Multi Function | ||
Time Increment Minutes, Seconds | ||
Maximum Current 3A | ||
Maximum Voltage 250V ac | ||
Switch Configuration 4PDT | ||
Terminal Type Socket | ||
Power Supply External | ||
Width 21.5mm | ||
Maximum Operating Temperature +50°C | ||
Depth 63mm | ||
Series H3YN | ||
Length 28mm | ||
Time Delay 0.1s | ||
Minimum Operating Temperature -10°C | ||
Omron H3YN Series Timer Relay, 24V AC Supply Voltage, 4PDT Switch Configuration - H3YN-4 AC24
This timer relay is designed for various applications in automation and control systems. The compact device features a DIN rail and panel mount design, making installation convenient in different environments. With its versatile operational modes and time range capabilities, this timer is essential for precise timing tasks.
Features & Benefits
• Multi-function capability allows selection of multiple operating modes
• Time range selectable from 0.1 seconds to 10 minutes
• Features flicker start options for customised operations
• External power supply ensures stable performance under varying loads
• Compact dimensions allow for effective space-saving in installations
• Time range selectable from 0.1 seconds to 10 minutes
• Features flicker start options for customised operations
• External power supply ensures stable performance under varying loads
• Compact dimensions allow for effective space-saving in installations
Applications
• Used for controlling electrical loads in industrial environments
• Ideal for requiring precise timing sequences
• Suitable for automation systems needing reliable on-delay timing
• Used in timer circuits to manage flicker start operations
• Integrates with other devices for enhanced control and automation systems
• Ideal for requiring precise timing sequences
• Suitable for automation systems needing reliable on-delay timing
• Used in timer circuits to manage flicker start operations
• Integrates with other devices for enhanced control and automation systems
How does the selectable time range enhance operational flexibility?
The selectable time range allows precise control of the timing intervals needed for various applications, ensuring efficient operation tailored to specific tasks.
In what scenarios is the flicker start mode particularly useful?
The flicker start mode is beneficial in situations where transient signals or oscillatory behaviours are needed, allowing devices to operate in a desired pattern without disrupting normal function.
What are the installation options for this device?
This unit can be easily mounted on both DIN rails and panels, providing flexibility in configuration to suit different installation environments.
How can this timer relay contribute to energy efficiency?
By allowing precise timing control, it prevents unnecessary operation of equipment, thus contributing to reduced energy consumption and operational costs.
What precautions should be considered during installation?
It is crucial to ensure that the installation environment is free from excessive dust or corrosive gases and to maintain an appropriate distance from other devices to allow for effective heat dissipation.
相关链接
- Omron H3YN Series DIN Rail 24V ac 0.1 s → 10min
- Omron H3YN Series Panel Mount Timer Relay 4-Contact DPDT
- Omron H3YN Series Panel Mount Timer Relay 4-Contact 4NO/4NC
- Omron H3YN Series DIN Rail 24V dc 0.1 s → 10min, 4PST
- Omron H3YN Series DIN Rail Mount Timer Relay 2-Contact, 0.1 s → 10min
- Omron H3YN Series Panel Mount Timer Relay 4-Contact 4NO/4NC
- Omron H3YN Series Panel Mount Timer Relay 4-Contact DPDT
- Omron H3YN Series DIN Rail 12V dc 0.1 s → 10min
