Omron H3Y Series Surface, DIN Rail Timer Relay, 4-Contact, 200 to 230 V, 60 s, 1-Function, DPDT Switch Configuration

此圖片僅供參考,請參閲產品詳細資訊及規格

小計(1 件)*

HK$686.00

Add to Basket
選擇或輸入數量
库存信息目前无法访问 - 请稍候查看
單位
每單位
1 +HK$686.00

* 參考價格

RS庫存編號:
794-8912
製造零件編號:
H3Y-2 AC200-230 60S
製造商:
Omron
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Omron

Product Type

Timer Relay

Mount Type

Surface, DIN Rail

Time Range

60 s

Number of Contacts

4

Number of Timer Functions

1

Switching Voltage

250V

Contact Configuration

DPDT

IP Rating

IP40

Contact Current

5A

Minimum Operating Temperature

-10°C

Supply DC Voltage

200 to 230 V

Maximum Operating Temperature

50°C

Height

28mm

Length

63.0mm

Width

21.5mm

Standards/Approvals

Lloyds, UL508, EN61812-1, CSA C22.2 No. 14, EN60947-5-1, IEC60664-1

Series

H3Y

Omron H3Y Series Timer Relay, 60s Time Range, 200 to 230V Supply DC Voltage - H3Y-2 AC200-230 60S


This timer relay provides time-delay switching for control circuits in industrial and automation settings, operating from an AC supply of 200–230V to deliver a fixed 60 s delay. It offers double-pole changeover contacts and is intended for mounting on a flat surface or onto DIN-rail systems, making it suitable for integration into control panels and machinery control loops.

Features and Benefits:


• DPDT contacts rated 5A for moderate current switching
• Time range set to 60 s to manage delayed operations
• Switching capability at 250V for AC load compatibility
• IP40 enclosure for protection against solid ingress in panels
• Operates between −10 °C and 50 °C for varied ambient conditions

Applications


• Suitable for sequencing motors in conveyor-control cabinets
• Used for delay control in industrial heating systems
• Ideal for timed switching in production machine controls
• Used with PLCs for auxiliary timing functions in panels

What contact arrangement is provided for interfacing with control circuits?


It uses a double-pole changeover configuration with four contacts to switch two independent circuits or provide common changeover functionality.

How should it be installed to comply with panel-layout needs?


It can be fitted to a DIN rail or secured by surface mounting to accommodate different enclosure arrangements and space constraints.

What approvals support its use in regulated electrical systems?


It carries recognised approvals including UL508, CSA C22.2 No.14, EN 60947-5-1, EN 61812-1 and relevant IEC standards for industrial electrical components.

What are the operating temperature limits to consider for equipment selection?


It is specified to function reliably between −10 °C and 50 °C, so ambient conditions outside this range require alternative solutions.

相关链接