Gossen Metrawatt METRISO PRIME Insulation Tester, 100 V Min, 5 kV Max, 100 GΩ CAT IV, CAT III, CAT II

小計(1 件)*

HK$23,157.30

Add to Basket
選擇或輸入數量
暫時缺貨
  • 從 2026年12月18日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$23,157.30

* 參考價格

RS庫存編號:
867-5630
Distrelec 貨號:
300-18-121
製造零件編號:
M550T
製造商:
Gossen Metrawatt
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Gossen Metrawatt

Product Type

Insulation Tester

Model Number

METRISO PRIME

Tester Type

Insulation Tester

Maximum Test Voltage

5kV

Minimum Test Voltage

100V

Display Type

Analogue

Test Current

1mA

Power Source

Battery

Battery Type

Type D

Insulation Testing Resistance

100GΩ

Minimum Operating Temperature

0°C

Safety Category Level

CAT IV, CAT III, CAT II

Maximum Operating Temperature

40°C

Safety Category Voltage

1kV

Length

250mm

Standards/Approvals

CE

Width

290mm

Height

140mm

Weight

3.4kg

COO (Country of Origin):
DE

Gossen-Metrawatt Insulation Tester, 5000V Maximum Test Voltage, 100GΩ Insulation Testing Resistance - M550T


This insulation tester is a battery-powered, analogue instrument designed to measure high resistance in electrical systems. It operates across a broad test-voltage range and is suitable for field use where portable diagnostics are required. The unit is intended for use within standard ambient temperatures and conforms to recognised safety approvals for industrial environments.

Features and Benefits:


• *Made in Germany
• 5000 V maximum test voltage provides wide-range dielectric assessment
• 100 GΩ insulation measurement supports detection of very high resistances
• 1 mA test current allows controlled energisation during tests
• Battery operation using Type D cells enables remote-site use
• CAT IV safety rating permits work on high-energy installations

Applications


• Used for verification of insulation on industrial switchgear
• Suitable for maintenance of electrical distribution networks
• Ideal for commissioning tests on high-voltage equipment
• Used for routine insulation diagnostics in plant environments
• Suitable for portable fault-finding across service installations

What supply does the instrument require to operate?


It runs from replaceable Type D batteries and is intended for off-mains use.

Which safety categories cover its intended use?


The device meets CAT IV, CAT III and CAT II safety levels for various installation points.

What display format is provided for readings?


Readouts are presented on an analogue scale to monitor measurement behaviour.

What environmental temperatures can it tolerate during operation?


It is rated to operate between 0°C and 40°C.