Druck UPS4E Loop Calibrator 4 x 1.5V AA Alkaline Batteries 30V dc

此圖片僅供參考,請參閲產品詳細資訊及規格

小計(1 件)*

HK$11,319.10

Add to Basket
選擇或輸入數量
有庫存
  • 20 件準備從其他地點送貨
  • 加上 6 件從 2026年11月17日 起發貨
  • 加上 16 件從 2026年12月08日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$11,319.10

* 參考價格

RS庫存編號:
639-653
製造零件編號:
UPS4E
製造商:
Druck
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Druck

Product Type

Loop Calibrator

Model Number

UPS4E

Accuracy

0.01 %

Battery Type

AA Alkaline

Battery Life

72h

Power Source

4 x 1.5V AA Alkaline Batteries

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

50°C

Width

73mm

Standards/Approvals

EN 61010-2-030:2023, EN 61010-1:2010, CE, EN 61326-1:2013, MIL-PRF-28800F CLASS 2

Weight

300g

Length

145mm

Height

25mm

Safety Category Voltage

30V dc

COO (Country of Origin):
CN

Druck Loop Calibrator, 0.01% Accuracy, Battery Powered - UPS4E


This loop calibrator functions as a handheld instrument for generating and measuring 4 to 20 mA control loops in field and workshop environments. It operates from four AA alkaline cells and is intended for routine calibration, fault finding and verification of current-loop instrumentation within typical industrial temperature ranges.

Features and Benefits:


• 0.01% accuracy delivers precise loop simulation and measurement
• Battery‑powered operation supports remote field work
• Safety category 30 V dc reduces exposure during measurements
• MIL‑PRF‑28800F Class 2 rating supports rugged deployment
• CE and EN 61326‑1:2013 compliance aids electromagnetic compatibility

Applications


• Suitable for commissioning control loop transmitters and valves
• Ideal for portable maintenance and on‑site calibration tasks
• Used with process control systems for routine verification
• Can be used for troubleshooting 4 to 20 mA signal faults
• Suitable for instrument technicians working across temperature ranges

What battery type does it require?


It uses four AA alkaline batteries and runs until the cells reach end of life.

How long will it operate on a fresh battery set?


Typical continuous operation is approximately 72 hours on new alkaline cells.

What environmental temperatures can it withstand during use?


It is rated to operate between -10 °C and 50 °C.

Which safety and performance standards does it meet?


The unit conforms to EN 61010‑2‑030:2023, EN 61010‑1:2010 and EN 61326‑1:2013, and holds MIL‑PRF‑28800F Class 2 recognition.