Fluke 705 Loop Calibrator
Fluke's integrated solution for calibration, maintenance of milliamp loops and repair, the 705 current loop calibrator is an ideal cost-effective source and measurement tool.
Delivering a mA accuracy of 0.02% it also provides quick and easy readings due to the simultaneous % and mA display. For 0 to 20 mA or 4 to 20 mA current loop testing and dc voltage from 0 to 28 V, it is supplied with a set of TL75 test leads (726-3624) and alligator clips.
Delivering a mA accuracy of 0.02% it also provides quick and easy readings due to the simultaneous % and mA display. For 0 to 20 mA or 4 to 20 mA current loop testing and dc voltage from 0 to 28 V, it is supplied with a set of TL75 test leads (726-3624) and alligator clips.
Features and Benefits:
0.02% accuracy
24 V loop supply with mA measure
Simultaneous mA and % of span display
Selectable step/ramp outputs
mA sourcing, simulation and measurement
Compact case and protective holster
Quick battery replacement
24 V loop supply with mA measure
Simultaneous mA and % of span display
Selectable step/ramp outputs
mA sourcing, simulation and measurement
Compact case and protective holster
Quick battery replacement
FAQ's
What is a current loop calibrator?
Current loop calibrators are specially designed instruments for current loop trouble shooting, testing and calibration. They can source current on unpowered devices in a loop, simulate the operation of loop powered transmitters and also measure current. These calibrators often feature time saving technology, specialist graphics using digital interfaces and micro-processor based electronics.
How much current flows in each loop of a parallel circuit?
Determined by Ohm's law, which states that the current between 2 points through a conductor is directly proportionate to the voltage across those 2 points, divided by the resistance of the conductor. I = V/R. This is also the case for series and parallel circuits, however in parallel circuits the total current can be affected by the way the resistors have been connected, as well as their ohmic value. Current does divide up and there can be more current in one area over another nonetheless when all areas are added up the total amount is the same.
Supplied with
9V installed alkaline battery, AC70A alligator clips, C10 protective yellow holster Flex-Stand™, instruction sheet, TL75 safety-designed test lead set, NIST- traceable calibration report and data
FLUKE Loop Calibrator, -10°C to +55°C Operating Temperature, Shock and Vibration Resistant - 705 Series - 0665091
Troubleshooting circuits is fuss-free with this loop calibrator from FLUKE. Use it to calibrate and test current loops so you can identify and repair faults promptly to keep your system running safely. You can expect precise current readings thanks to the unit's tight mA accuracy of 0.02%. The results are quick and easy to interpret too, as having readouts as both mA and % means you always get the full picture. As it's protected by a handy yellow holster, this gadget withstands knocks for reliable use in demanding industrial settings.
Features & Benefits
Helpful for linearity checks thanks to its dedicated push button for 25% increments
Switchable between stepped or ramped output to meet your application needs
9V battery is easy to change without opening the case and affecting the calibration seal
'Span check' function gives you speedily calculated results for zero and span measurements
Switchable between stepped or ramped output to meet your application needs
9V battery is easy to change without opening the case and affecting the calibration seal
'Span check' function gives you speedily calculated results for zero and span measurements
Applications
Test and measurement devices
Research and development labs
Electronics servicing
Research and development labs
Electronics servicing
What's the benefit of this product's internal loop supply?
This product's 24V internal loop supply provides advanced functionality, as it lets you power and read a transmitter at the same time. This eliminates the need for a separate digital multimeter and PSU.
Attribute | Value |
---|---|
Absolute Maximum Current Measurement | 24mA |
Best Accuracy | ±0.025 % |
Resolution | 0.001 mA |
Safety Category | CSA C22.2 |
Battery Type | A, AA |
Battery Life | 18 h |
Power Source | Battery |
Dimensions | 152 x 70 x 41mm |
Weight | 340g |
Height | 164mm |
Length | 47mm |
Maximum Operating Temperature | +55°C |
Minimum Operating Temperature | -10°C |
Model Number p | 705 |
Width | 75mm |
Safety Category Voltage | 30V |