Gossen Metrawatt M516L Electrical Installation Tester 1000V Earth Resistance Measurement With RS232

小計(1 件)*

HK$88,813.30

Add to Basket
選擇或輸入數量
暫時缺貨
  • 2026年4月15日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$88,813.30

* 參考價格

RS庫存編號:
145-587
製造零件編號:
M516L
製造商:
Gossen Metrawatt
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Gossen Metrawatt

Product Type

Electrical Installation Tester

Loop Impedance Test Type

High/Low Current

Automatic RCD Test

Yes

RCD Ramp Test

Yes

Model Number

M516L

Non-Tripping

No

Insulation Test Voltage

1000V

Maximum Voltage Measurement

10V

Test Type

RCD Test

Earth Resistance Measurement

Yes

Downloadable Data

Yes

Interface Type

RS232

RCD Test Type

AC, Type B, B+, F

Height

21cm

Width

50cm

Standards/Approvals

DIN EN 50191, DIN EN 62446-1, VDE 0113-1, IEC 60364-7-710, IEC 60364-6, IEC 61851-1, IEC 62446-1, VDE 0104, DIN EN 61851-1, VDE 0100-710, NIV, EN 50110-1, SN 411000, DIN EN 60204-1, VDE 0432-1, IEC 60204-1, VDE 0105-100, VDE 0472, DIN EN 61557-14, VDE 0660-600-1, DIN VDE 0472, DIN VDE 0100-710, IEC 61557-14, VDE 0100-600, VDE 0126-23-1, DIN VDE 0100-600, VDE 0413-14, DIN EN IEC 61439-1, IEC 60060-1, DIN EN 60060-1, VDE 0122-1, OVE E 8101

Remote Switch Mode

Yes

Length

41cm

IP Rating

IP40

Test Standards

IEC 61326-2-1, DIN EN 61326-1, IEC 61010-1, DIN EN 61010-2-032, IEC 61010-2-032, DIN EN 60529, IEC 61326-1, IEC 61010-031, DIN EN 61010-031, DIN EN 61557-1 bis -14, IEC 60529, IEC 61010-2-030, DIN EN 61010-2-030, IEC 61557-1 bis -14, DIN EN 61010-1, DIN EN 61326-2-1

Safety Category Voltage

600V

Power Source

85 V to 264 V, 3 x Lithium-Ion Batteries

Safety Category Level

CAT III 600 V CAT IV 300 V

Display Type

LCD Backlight

Battery Type

Lithium-ion

Maximum Operating Temperature

50°C

Minimum Continuity Resistance

Minimum Operating Temperature

5°C

Maximum Continuity Resistance

200Ω

COO (Country of Origin):
DE
The Gossen Metrawatt test instrument is versatile all in one test instruments for use in AC and DC networks for market compliant testing of the effectiveness of protective measures at electrical systems or installations, electric machines, PV systems and electric charging stations. It can also be used for high voltage testing. It is ideal for installation, initial startup, periodic testing and troubleshooting.

Phase sequence testing

Measurement of insulation resistance RINS

Measurement of residual voltage without tripping the RCD

Measurement of tripping current with ramp function