Fluke calibration 9100S-C-256 Temperature Calibrator

小計(1 件)*

HK$30,368.20

Add to Basket
選擇或輸入數量
新產品 - 立即預訂
  • 1 件從 2027年1月28日 起裝運發貨
  • 加上 6 件從 2027年2月25日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +HK$30,368.20

* 參考價格

RS庫存編號:
284-2720
製造零件編號:
9100S-C-256
製造商:
Fluke calibration
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Fluke calibration

Calibrator Type

Drywell Calibrator

Product Type

Temperature Calibrator

Resolution

0.1 °C

Accuracy

±0.25°C

Thermocouple Type

RTD

Temperature Scale

Centigrade, Fahrenheit

Minimum Thermocouple Temperature

-10°C

Width

125mm

Standards/Approvals

No

Height

57mm

Length

150mm

Weight

1kg

COO (Country of Origin):
US

Fluke Temperature Calibrator, ±0.25°C Accuracy, 0.1°C Resolution - 9100S-C-256


This temperature calibrator is a handheld dry-well device designed for portable verification of industrial temperature sensors. It provides a compact, field-ready solution for checking RTDs, thermocouples and small bimetal thermometers across a wide temperature span while offering selectable display in °C or Fahrenheit.

Features and Benefits:


• Accuracy ±0.25°C at 50°C for precise measurement assurance
• Resolution 0.1°C for fine-grain comparison of sensors
• Stabilisation time 5 minutes to reduce downtime during checks
• RS-232 interface for straightforward data exchange with computers
• Weight 1 kg enabling easy transport between sites
• Well depth 102mm to accommodate short-length probes

Applications


• Suitable for on-site verification of RTD sensors in process plants
• Ideal for thermocouple checking in maintenance routines
• Used with small bimetal thermometers for quick field audits
• Can be used for laboratory checks of RTD components
• Applicable to calibration of industrial temperature sensors in situ

What power options are available for field operation?


It accepts mains power at standard voltages and frequencies

power consumption varies with supply configuration and heating demand.

How quickly does it heat from ambient to elevated temperatures?


Typical heating time from 35°C to 375°C is approximately 9.5 minutes, enabling rapid test cycles.

Which sensor insertion sizes are supported?


The well accepts probes accommodated by supplied and optional removable inserts for differing probe diameters.

What uniformity can be expected across the well?


Well-to-well uniformity is maintained within tight limits when sensors of similar size are placed at equal depths.