Fluke 1550C FC Insulation Tester, 250 V Min, 5 kV Max, 1 TΩ CAT III, CAT IV
- RS庫存編號:
- 175-7821
- 製造零件編號:
- FLUKE-1550C FC w/IR3000
- 製造商:
- Fluke
暫時無法供應
抱歉,我們不知道何時會到貨。
- RS庫存編號:
- 175-7821
- 製造零件編號:
- FLUKE-1550C FC w/IR3000
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Product Type | Insulation Tester | |
| Model Number | 1550C FC | |
| Tester Type | Insulation Tester | |
| Minimum Test Voltage | 250V | |
| Maximum Test Voltage | 5kV | |
| Display Type | LCD | |
| Test Current | 2nA | |
| Power Source | Battery | |
| Battery Life | 750Tests | |
| Battery Type | Rechargeable Lead Acid (Yuasa NP2.8-12) | |
| Minimum Operating Temperature | -20°C | |
| Insulation Testing Resistance | 1TΩ | |
| Safety Category Level | CAT III, CAT IV | |
| Safety Category Voltage | 1kV, 600kV | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | IEC 61010-1, IEC 61010-2-030, IEC 61557-1, IEC 61557-2 | |
| Length | 277mm | |
| Height | 160mm | |
| Width | 269mm | |
| Weight | 3.7kg | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Product Type Insulation Tester | ||
Model Number 1550C FC | ||
Tester Type Insulation Tester | ||
Minimum Test Voltage 250V | ||
Maximum Test Voltage 5kV | ||
Display Type LCD | ||
Test Current 2nA | ||
Power Source Battery | ||
Battery Life 750Tests | ||
Battery Type Rechargeable Lead Acid (Yuasa NP2.8-12) | ||
Minimum Operating Temperature -20°C | ||
Insulation Testing Resistance 1TΩ | ||
Safety Category Level CAT III, CAT IV | ||
Safety Category Voltage 1kV, 600kV | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals IEC 61010-1, IEC 61010-2-030, IEC 61557-1, IEC 61557-2 | ||
Length 277mm | ||
Height 160mm | ||
Width 269mm | ||
Weight 3.7kg | ||
- COO (Country of Origin):
- US
Fluke Insulation Tester, 5 MΩ to 1 TΩ Insulation Testing Resistance, 250V to 5000V Test Voltage - FLUKE-1550C FC w/IR3000
This insulation tester is a portable instrument for assessing insulation resistance on high-voltage electrical assets and supporting preventive maintenance programmes. It operates from an internal lead‑acid battery and pairs with a wireless connector and mobile app to capture, trend and store measurement data remotely, improving on-site decision making and worker safety during tests.
Features & Benefits
• Selectable test voltages from 250V to 5000V enabling tailored diagnostics
• Measures insulation resistance up to 1TΩ for high-resistance detection
• Rechargeable Yuasa NP2.8-12 battery powered tester offering 750 tests
• CAT IV 1000V safety rating for use on industrial distribution systems
• Guard system reduces surface leakage influence for cleaner readings
• Timer function to 99 minutes for controlled timed measurements
• Measures insulation resistance up to 1TΩ for high-resistance detection
• Rechargeable Yuasa NP2.8-12 battery powered tester offering 750 tests
• CAT IV 1000V safety rating for use on industrial distribution systems
• Guard system reduces surface leakage influence for cleaner readings
• Timer function to 99 minutes for controlled timed measurements
**Applications**
• Suitable for insulation assessment of switchgear and transformers
• Ideal for motor and generator insulation condition monitoring
• Used for cable acceptance testing and site commissioning
• Can be used with asset trending systems for predictive maintenance
• Ideal for motor and generator insulation condition monitoring
• Used for cable acceptance testing and site commissioning
• Can be used with asset trending systems for predictive maintenance
What range of resistance can I expect to measure accurately?
The instrument provides resistance measurement capability up to 1TΩ and includes a bar-graph visualisation for large-range readings.
How is live-voltage presence handled before a test?
It warns of line voltage presence and displays voltages up to 600V AC/DC so users can confirm circuits are safe to test.
What environmental conditions does it tolerate during operation?
It functions between -20°C and 50°C with humidity ratings that decline from 80% at 31°C to 50% at 50°C and is specified for use up to 2000m altitude.
What measurements beyond resistance does it perform?
It measures leakage current from 1nA to 2mA, capacitance up to 20.00μF, and offers a ramp test for breakdown evaluation.
Contents
1550C FC w/IR3000FC 175-7821
Test cables with alligator clips (red, black, green)
Infrared adapter with Interface cable
AC power cord
Soft carrying case
English manual
User's manual on CD-ROM
Quick reference card
Software license agreement
Registration card
USB-IR cable installation guide
Test cables with alligator clips (red, black, green)
Infrared adapter with Interface cable
AC power cord
Soft carrying case
English manual
User's manual on CD-ROM
Quick reference card
Software license agreement
Registration card
USB-IR cable installation guide
相关链接
- RS PRO Black Nylon Cable Gland 5mm Min IP68
- Schneider Electric Analogue DIN Rail Time Switch 250 V ac, 1-Channel
- Belden Cat6 Ethernet Cable Blue LSZH Sheath, 304m
- Prysmian 6491B Series Green/Yellow 2.5 mm² Hook Up Wire 100m
- https://hkcn.rs-online.com/web/p/coaxial-cable/2662163
- Siemens SIMATIC S7-1200 Series PLC CPU for Use with SIMATIC S7-1200 Series Digital, Relay
- ebm-papst 4400 F Series Axial Fan DC Operation 5.3W 119 x 119 x 25mm
- RS PRO 2 Core Power Cable 1000, 600 V