Fluke 1550C FC Kit Insulation Tester, 250 V Min, 5000 V Max, 1 TΩ CAT IV, CAT III
- RS庫存編號:
- 175-7822
- Distrelec 貨號:
- 301-16-483
- 製造零件編號:
- FLUKE-1550C FC Kit w/IR3000
- 製造商:
- Fluke
小計(1 件)*
HK$71,798.40
訂單超過 HK$250.00 免費送貨
有限的庫存
- 1 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | HK$71,798.40 |
* 參考價格
- RS庫存編號:
- 175-7822
- Distrelec 貨號:
- 301-16-483
- 製造零件編號:
- FLUKE-1550C FC Kit w/IR3000
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Model Number | 1550C FC Kit | |
| Product Type | Insulation Tester | |
| Tester Type | Insulation Tester | |
| Minimum Test Voltage | 250V | |
| Maximum Test Voltage | 5000V | |
| Display Type | LCD | |
| Test Current | 2000000nA | |
| Power Source | Battery | |
| Battery Type | Rechargeable Lead Acid (Yuasa NP2.8-12) | |
| Minimum Operating Temperature | -20°C | |
| Insulation Testing Resistance | 1TΩ | |
| Maximum Operating Temperature | 50°C | |
| Safety Category Level | CAT IV, CAT III | |
| Safety Category Voltage | 600, 1000V | |
| Length | 277mm | |
| Standards/Approvals | CE, CSA | |
| Width | 269mm | |
| Height | 160mm | |
| Weight | 3.7kg | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Model Number 1550C FC Kit | ||
Product Type Insulation Tester | ||
Tester Type Insulation Tester | ||
Minimum Test Voltage 250V | ||
Maximum Test Voltage 5000V | ||
Display Type LCD | ||
Test Current 2000000nA | ||
Power Source Battery | ||
Battery Type Rechargeable Lead Acid (Yuasa NP2.8-12) | ||
Minimum Operating Temperature -20°C | ||
Insulation Testing Resistance 1TΩ | ||
Maximum Operating Temperature 50°C | ||
Safety Category Level CAT IV, CAT III | ||
Safety Category Voltage 600, 1000V | ||
Length 277mm | ||
Standards/Approvals CE, CSA | ||
Width 269mm | ||
Height 160mm | ||
Weight 3.7kg | ||
Fluke Insulation Tester, 5000V Maximum Test Voltage, 5MΩ to 1TΩ Insulation Testing Resistance - FLUKE-1550C FC Kit w/IR3000
This insulation tester is a portable instrument for assessing high-voltage insulation resistance on switchgear, motors, generators and cables in industrial maintenance and troubleshooting workflows. It supports selectable DC test voltages from 250V up to 5000V and offers wireless data capture via an infrared-to-wireless connector and mobile app, enabling remote control and trend visualisation while reducing time spent on manual record-keeping.
Features & Benefits
• Test voltage range 250 V–5000V enabling wide application coverage
• Insulation resistance measurement up to 1 TΩ for high-resistance detection
• Rechargeable lead-acid battery providing extended testing between charges
• CAT IV 600 V, CAT III 1000V safety ratings for field personnel protection
• Built-in guard system minimises surface leakage effects during measurement
• Timer function to 99 minutes for automated timed test sequences
• Insulation resistance measurement up to 1 TΩ for high-resistance detection
• Rechargeable lead-acid battery providing extended testing between charges
• CAT IV 600 V, CAT III 1000V safety ratings for field personnel protection
• Built-in guard system minimises surface leakage effects during measurement
• Timer function to 99 minutes for automated timed test sequences
**Applications**
• Suitable for preventative maintenance of industrial motors and generators
• Ideal for commissioning and troubleshooting of medium-voltage switchgear
• Used for cable insulation health checks on power distribution networks
• Can be used with condition-monitoring programmes for trend analysis
• Ideal for commissioning and troubleshooting of medium-voltage switchgear
• Used for cable insulation health checks on power distribution networks
• Can be used with condition-monitoring programmes for trend analysis
What battery chemistry and charger input does it use?
It uses a 12V lead-acid rechargeable battery (Yuasa NP2.8-12) and accepts 85 V–250V AC 50/60 Hz charger input.
How does the instrument handle capacitive tests and discharges?
The charger supports charging at approximately 5 s per μF and discharges at about 1.5 s per μF for capacitive loads.
What measurements beyond resistance can it perform?
It measures leakage current from 1 nA to 2 mA and capacitance from 0.01 μF to 20.00 μF with stated accuracy limits.
What environmental limits apply during operation?
Operating temperature spans -20 °C to 50 °C with humidity up to 80% at 31 °C, reducing linearly to 50% at 50 °C.
What interfaces and storage capabilities are available?
Results can be transmitted via the infrared-to-wireless connector to the mobile app for remote start/stop, trending and secure storage.
Contents
Fluke 1550C FC Kit w/IR3000FC 175-7822
Test cables with alligator clips (red, black, green)
Infrared adapter with Interface cable
AC power cord
Hard Case
English manual
User's manual on CD-ROM
Quick reference card
Software license agreement
Registration card
USB-IR cable installation guide
Heavy duty alligator clip leads
Certificate of Calibration
Test cables with alligator clips (red, black, green)
Infrared adapter with Interface cable
AC power cord
Hard Case
English manual
User's manual on CD-ROM
Quick reference card
Software license agreement
Registration card
USB-IR cable installation guide
Heavy duty alligator clip leads
Certificate of Calibration
相关链接
- Fluke 1550C FC Insulation Tester 5000 V Max CAT III, CAT IV
- Fluke 1555 FC Insulation Tester 10000 V Max CAT III
- Fluke 1550C Insulation Tester 5000 V Max CAT IV, CAT III
- Fluke 1630-2 FC Earth Tester CAT IV 1000V
- Fluke 1587 FC Insulation Tester 1000 V Max CAT III
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke A3001 FC Clamp Meter 2500 A CAT IV, CAT III Non-Contact Voltage Detector
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector